About Autoclave Autoclave Non Electrical
Non Electric Autoclave
Brand : - Standard Steel
Silent features
- Strong Seamless thick Aluminum sheet construction for better safety and Durablility.
- syntactic Rubber Gasket for long term performance.
- equipped with color coded pressure gauge.
- Double heavy duty steam release pressure safety valve for safety purpose.
- heavy duty handles.
- Operating Pressure 15-18 psi
- Total Sterilization 20-30 minutes
Available sizes
- 300 x 350 mm or 25 liter.
- 300X500 MM or 35 liter.
- 350 x 450 mm or 45 liter.
- 450 x 375 mm or 60 liter
- 450 x 450 mm or 80 liter
Portable and Durable DesignBuilt from strong aluminum, this lightweight autoclave is easy to transport and set up in any medical or laboratory environment. The vertical cylindrical form factor and secure lid system provide a reliable and ergonomic sterilization solution while ensuring user safety.
Manual, Non-Electric OperationDesigned for manual use, this autoclave needs no electricity, making it suitable for areas with limited power supply. The process is simple: just add water, secure the lid, and monitor the pressure gauge during the sterilization cycletotaling 1520 minutes at full pressure.
Enhanced Safety FeaturesA pressure release valve and robust wing nut locking system reduce risks during use, while the rubber gasket (silicone or neoprene) ensures an airtight seal. The unit also comes with a one-year warranty for additional peace of mind.
FAQs of Autoclave Autoclave Non Electrical:
Q: How do I operate the non-electrical autoclave for sterilization?
A: To operate the autoclave, fill it with the required amount of water, load your instruments, and securely lock the dome-shaped lid using the wing nut system. Monitor the pressure gauge to ensure it reaches 15 psi. Maintain this pressure for 1520 minutes before releasing pressure through the safety valve and removing sterilized items.
Q: What materials can be sterilized in this manual autoclave?
A: This autoclave is suitable for sterilizing a variety of laboratory and medical items like glassware, metal instruments, and heat-resistant materials commonly used in clinics and laboratories.
Q: When is this autoclave most beneficial to use?
A: This non-electrical model is especially valuable in settings where electrical power is unreliable or unavailable, or during fieldwork, remote clinics, and mobile laboratory services.
Q: Where can this portable autoclave be used effectively?
A: Due to its portable design and manual operation, it is ideal for hospitals, clinics, laboratories, dispensaries, field locations, and mobile medical units throughout India.
Q: What are the key safety measures integrated into this equipment?
A: The autoclave features a pressure release valve, a durable dome-shaped lid with a wing nut locking system, and a rubber gasket to prevent leaks, all contributing to safe daily operation.
Q: What is the benefit of the temperature resistance up to 121C?
A: Withstanding temperatures up to 121C ensures effective sterilization, killing bacteria and spores reliably, thus meeting general laboratory sterilization requirements.
Q: How often should the gasket and safety valves be checked or replaced?
A: Regular inspections after each cycle are recommended. Replace the silicone or neoprene gasket and inspect the pressure release valve periodically, or anytime there are signs of wear or loss of airtightness.