Back to top
Manual Blood Cell Counter 5 and 8 Key
Manual Blood Cell Counter 5 and 8 Key
Manual Blood Cell Counter 5 and 8 Key
Manual Blood Cell Counter 5 and 8 Key
Manual Blood Cell Counter 5 and 8 Key
Manual Blood Cell Counter 5 and 8 Key

Manual Blood Cell Counter 5 and 8 Key

Manual Blood Cell Counter 5 and 8 Key Specification

  • Temperature Resistance
  • Standard laboratory ambient temperature
  • Power Supply
  • Not Required
  • Features
  • 5 and 8 key models available, easy reset knob, compact design, durable construction, no batteries required
  • Shape
  • Rectangular
  • Display Type
  • Mechanical Resettable Counter
  • Accuracy
  • High counting accuracy
  • Control Type
  • Manual push button
  • Type
  • Manual Blood Cell Counter
  • Dimension (L*W*H)
  • Approx. 245 x 80 x 50 mm
  • Product Type
  • Blood cell counter
  • Equipment Type
  • Manual Blood Cell Counter
  • Equipment Materials
  • Plastic body with mechanical tally system
  • Color
  • white and black
  • Power
  • Not Required (Manual Operation)
  • Material
  • ABS Plastic and Metal Components
  • Application
  • Blood cell counter
  • Warranty
  • 1 year
 

Manual Blood Cell Counter 5 and 8 Key Trade Information

  • Minimum Order Quantity
  • 30 Pieces
  • FOB Port
  • exw
  • Payment Terms
  • Telegraphic Transfer (T/T)
  • Supply Ability
  • 500 Per Month
  • Delivery Time
  • 15 Days
  • Sample Available
  • Yes
  • Sample Policy
  • Sample costs shipping and taxes has to be paid by the buyer
  • Packaging Details
  • Standard Packing
  • Main Export Market(s)
  • Asia
  • Main Domestic Market
  • All India
  • Certifications
  • ISO CE
 

About Manual Blood Cell Counter 5 and 8 Key

Manual Blood Cell Counter 8 Key Standard Steel

  • ABS outer shell can resist collision.
  • counts(BASO, EOSIN, MONO, LYMPH, JUVEN, STAB, SEG, MYELO).
  • At one hundred increment of the total record, the bell sound be heard.
  • Rest knob can easily clear all figures.
  • Eight Keys and one totalizer.
  • Figure range for each window (including the totalizer) is from 0 - 999.
  • packed in laminated card board box, duly covered with Thick Foam.
  • available in 2, 5 and 8 keys.

 

 

 

Blood cell counter Manufacturer, Blood cell counter Exporter, Blood cell counter Supplier, Blood cell counter Manufacturer in India

 



Effortless Manual Operation

This blood cell counter is designed for single-handed, manual use. With its push-button keys and smooth mechanical tally system, lab technicians can swiftly increment counts without needing any electrical power. The reset knob provides an easy way to quickly restore each counter to zero after completing counts.


Durability and Portability Combined

Constructed from ABS plastic and metal, the counter features a sturdy yet lightweight design, weighing only approximately 220 grams. Its compact form factor allows it to fit comfortably on tables or be carried between stations, ideal for laboratories that require mobility or space efficiency.


Versatile and Reliable Laboratory Solution

Available in both 5 and 8 key versions, this manual cell counter suits a variety of differential counting applications. Its high accuracy and mechanical reliability make it a trusted choice for hematology labs, with no batteries or external power supplies neededjust reliable, mechanical precision.

FAQs of Manual Blood Cell Counter 5 and 8 Key:


Q: How do I use the manual blood cell counter for differential cell counting?

A: To use the counter, simply press the corresponding key each time a particular type of blood cell is identified during examination. The mechanical system increments the count for each press, and each key can register up to 999 counts. After finishing, use the knob to reset all counters to zero.

Q: What are the benefits of a manual blood cell counter compared to digital models?

A: Manual blood cell counters operate without the need for batteries or electricity, ensuring reliability and uninterrupted operation. They are practical in labs with limited power facilities and boast simple, robust construction, making them easy to maintain and less susceptible to electronic malfunction.

Q: When should I reset the cell counter, and how is it done?

A: The counter should be reset after each blood sample analysis to ensure accurate results for the next count. Simply turn the mechanical knob to bring every keys tally back to zero. This process is quick and requires no special tools.

Q: Where can this device be used most effectively?

A: This counter is most effective in hematology laboratories for manual differential cell counting, but its portable, compact design also makes it ideal for field clinics, research labs, or educational settings.

Q: What materials are used in the counter, and how does this impact its durability?

A: The counter is made with ABS plastic and metal components, offering a balance of lightness and strength. These materials enhance the devices resilience to daily wear, provide easy cleaning, and ensure a long service lifespan even under regular laboratory use.

Q: Is any power supply required for the operation of this counter?

A: No external power or batteries are needed. The counters entirely mechanical operation makes it suitable for any laboratory environment regardless of electricity availability.

Q: How do I maintain or clean the manual blood cell counter?

A: Maintenance is simplejust wipe the smooth, easy-to-clean surface with a mild disinfectant as needed. Avoid submerging the device in liquid and ensure the keys and reset knob operate smoothly for optimal longevity.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Laboratory Equipment Category

Biosafety Cabinets For Microbiology Lab

Biosafety Cabinets For Microbiology Lab

Price 90000.0 INR

Minimum Order Quantity : 1 Pieces

Application : Biosafety Cabinet

Power : 220 W

Material : Stainless Steel (Work Surface), Galvanized Steel Body

Voltage : 220 V / 50 Hz

Soxhlet Extraction Units

Soxhlet Extraction Units

Price 16500.0 INR

Minimum Order Quantity : 1

Application : Soxhlet Extraction Apparatus

Power : 500 W per heating mantle

Material : Borosilicate Glass and Metal Body

Voltage : 220 Volt (v)

Laboratories Vortex Shaker

Laboratories Vortex Shaker

Price 3000.0 INR

Minimum Order Quantity : 1 Pieces

Application : Mixing liquids in test tubes, vials, and small containers

Power : 60 W

Material : ABS plastic, highgrade rubber for top cup

Voltage : 220 V / 5060 Hz

Seed Germination Chamber

Seed Germination Chamber

Price 85000.0 INR

Minimum Order Quantity : 1

Application : Seed germinator

Power : 230V, 50Hz, Single Phase

Material : Mild Steel, Inner Stainless Steel Chamber

Voltage : 220240V AC